When it comes to the lines connecting master and secondary panels, where the line will carry as much as a full 100 amps, use a 2-gauge non-metallic sheathed electrical cable. The cable must contain one or two hot wires depending on your needs, one neutral wire, and one ground wire. Each wire should be 2-gauge in size.
What size wire do I need to run 100 Amp Service 150 feet?
What is the right wire size for 100 Amp service 150 feet distance? You should get 2/0 AWG Copper wire or 4/0 AWG Aluminum wire for single-phase circuits. And, 1/0 AWG Copper wire or 3/0 AWG Aluminum wire if you have three-phase circuits. For these wires, the average voltage drop should be 3%.Apr 28, 2021
Can you use 6 gauge wire for 100 amp service?
You can feed as many 100A subpanels as you want with #6 wire, as long as the wire is supplied from 60A breakers. Breakers protect wires.Mar 13, 2018
What size ground wire do I need for a 100 amp subpanel?
You are correct that for a 100A feeder, the associated ground wire needs to be an 8AWG copper or 6AWG aluminum wire.Jan 21, 2019
What size wire do I need to run a 100 amp service 200 feet?
To feed a 100 ampere secondary panel 200 ft. from the main panel, you'll want to use 1 AWG copper or 2/0 aluminum conductors. This is large enough to safely carry 100 amperes, and to maintain power quality over the distance.
What size wire do I need for a 100 amp underground 300 ft run?
for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit must still be rated underground wire and required by code also) Also note the size wire the breaker can handle, cannot cut strands to make fit, ...May 19, 2020
What size wire do I need for a 100 amp underground 150 ft run?
What is the right wire size for 100 Amp service 150 feet distance? You should get 2/0 AWG Copper wire or 4/0 AWG Aluminum wire for single-phase circuits. And, 1/0 AWG Copper wire or 3/0 AWG Aluminum wire if you have three-phase circuits. For these wires, the average voltage drop should be 3%.Apr 28, 2021